Quantity | Unit price |
---|---|
1 to 49 |
€36.77*
|
50 to 99 |
€34.93*
|
From 100 |
€33.09*
|
Overview
Description
Active termination for 1-Wire networks
In a 1-Wire network, the 1-Wire Term 1 provides a defined termination at the end of the 1-Wire network, thus ensuring a stable and professional 1-Wire network. The 1-Wire Term 1 is therefore a basic component of every 1-Wire network. The module contains a passive and active terminating resistor and a signaling of bus activity.
The active termination (1-Wire Term 1) is highly recommended to increase the maximum line length and improve the system stability of the 1-Wire network, especially for long 1-Wire lines and for a star or tree topology setup.
In a 1-Wire network, up to 3 1-Wire Term 1 modules can be connected.
The 1-Wire Term 1 is very compact and can be ideally installed in a flush-mounted box.
Function | Termination for 1-Wire networks, active |
Channel | 1 channel |
Operating voltage | 5VDC, max. 5mA |
Display | 2, LED for power and 1-Wire data |
Miscellaneous | Integrated overvoltage and reverse polarity protection |
Dimensions | 40x40x25mm (LxWxH) |
Scope of delivery | Module and operating instructions |
Integration into 1-Wire network
The 1-Wire Term 1 module is mounted at the end of a 1-Wire network cable.
If the 1-Wire network is star-shaped, i.e. with several 1-Wire cable sections, a 1-Wire Term 1 module should be connected to each end.
You should not use more than three 1-Wire Term 1 modules in a 1-Wire network.
Linear Topology
The structure corresponds to the linear topology with the difference that the slaves are connected to the main line via cables with a length of more than 3m (branch, stub).
Star or tree topology
The network is divided into several large strings at or near the 1-Wire bus coupler / 1-Wire controller /1-Wire hub (bus master). Sensors and actuators (e.g. switching modules) are connected at the end or along the respective string.
For more information, please refer to the operating instructions under Links/Downloads.
Properties
Execution: | 4 pin connector |
---|---|
Mounting: |
|
Number of inputs / outputs: | 1-Wire Bus Interface |
Plug and Play support , Auto-E-Connect Support: | No |
Protection circuit: |
|
Data interface: | Industrial 1-Wire Bus (5V, 1-Wire Data and Ground (GND), Functional Earth (FE)) |
Function: | Accessories |
1-Wire Interface: | Standard 1-Wire bus functions |
Versions: | Professional Version / Professional Series |
Power supply, Supply Voltage: | System supply, 5VDC (1-Wire main voltage) |
Connection type: | Screw terminal/s for cable up to 2.5qmm (~ AWG 13) cross-section |
Dimensions: | 40 x 40 x 25mm (LxWxH) |
Colour: | green |
Ingress Protection (IP = protection class according to DIN EN 60529), protection class (DIN EN 61140 (VDE 0140-1): |
|
Temperature range, operation: | -5°C to +50°C, standard temperature range |
Humidity Operation / Storage: | 10% to 92% (non-condensing) |
Temperature range, storage: | -5°C to +50°C, Standard temperature range |
Scope of delivery: | Device and Quick Guide, the User Guide (Manual) can be found in the download area as a PDF download. |
Design / Manufacturer: | ESERA |
Login
Device Documentation | Operating instructions, connection diagram, conformity, ... |
Info Material | Product catalogue, Brochures |
Technical Downloads | Software & co. |
Worth knowing | Wikis, entries, tutorials |