PLUG and PLAY
USER FRIENDLY
SECURE
DURABLE
ECO FRIENDLY

Central power supply for 1-Wire bus, 1-Wire hub

The 1-Wire Hubs (IV DC or III DC) act as central modules for building a 1-Wire network.

Application:

They provide 5VDC and 12VDC voltage to 1-Wire components, decoupling the voltage of the 1-Wire input and distributing the 1-Wire data line. The hubs can be ideally combined with a 1-Wire Bus Coupler (USB, Ethernet, or Serial) or 1-Wire Controller 1 and 1-Wire Controller 2. The input voltage of the 1-Wire Hubs is specifically tailored for system environments with direct current power supply, such as PLC controls.

Equipment / Function:

  • Central power supply of the 1-Wire network and 1-Wire distribution
  • LED indicators for Power and 1-Wire activity

1-Wire Repeater for Long Cable Runs

The 1-Wire Repeater is used to amplify or regenerate data signals in 1-Wire networks.

Application:

By employing repeaters, a 1-Wire network can be expanded, leading to a noticeable enhancement of network stability. Particularly recommended for networks with a "star topology".

Equipment / Function:

The repeater is simply integrated into a 1-Wire cable. No software is required for the 1-Wire Repeater.

Additional information about the fundamental 1-Wire components.

Shipping until
1-Wire Hub III DC, central power supply
1-Wire Hub III DC, central power supply and distribution for the 1-Wire network with 24VDC input voltage. The 1-Wire Hub III DC is the central module for building a 1-Wire network. The 1-Wire Hub III DC supplies the 1-Wire network with 5V and 12V voltage and distributes the 1-Wire data line. 1-Wire Hub III DC can be ideally combined with a 1-Wire bus coupler (USB, Ethernet or serial) or 1-Wire controller. The input voltage of the 1-Wire Hub III DC is nominally 24VDC (18-36VDC) and is therefore especially suited for system environments with DC voltage supply, such as PLC controls. Equipment / Function: Central power supply of the 1-Wire network 1-Wire distribution for several bus sections LED display for power and 1-Wire activity Measurement function for the output voltages (voltage and current measurement for the 5V and 12V output)Note: The device has no repeater function for the 1-Wire data signal, which means that the device does not increase the possible network size.Note: The device has no repeater function for the 1-Wire data signal, which means that the device does not increase the possible network size.

From €70.11*

Product number: 11322

Instantly available
Shipping until , if you place your order within the next .
Shipping until
1-Wire Repeater V2
Repeater V2 (signal amplifier) for 1-Wire networks New, reinforced version! features: The repeater is used for amplification or regeneration of data signals in 1-Wire networks. By using repeaters, a 1-Wire network can be expanded and a significant increase in network stability can be achieved. Especially recommended for networks with "star structure". (More about the 1-Wire topology can be found here) The repeater is simply connected in a 1-Wire cable. No software required. It supports all types of 1-Wire masters, such as USB adapter, 1-Wire bus coupler or solution with microcontroller with 5V signal level. The repeater is simply connected to the data, ground and 5V supply line of an existing 1-Wire network. The 12V voltage is led past the repeater. No additional power supply or configuration is required for the repeater. Function Signal amplifier for 1-Wire network, preferred for long label lines input and output 5V, 1-Wire data and ground (GND) Power supply 5VDC/approx. 15mA Dimensions 17 x 90 x 70mm (WxHxD), intended for top hat rail housing Connection Screw terminals Scope of delivery Module and operating instructions

From €44.01*

Product number: 11318

Instantly available
Shipping until , if you place your order within the next .
Shipping until
1-Wire Term 1
Active termination for 1-Wire networks In a 1-Wire network, the 1-Wire Term 1 provides a defined termination at the end of the 1-Wire network, thus ensuring a stable and professional 1-Wire network. The 1-Wire Term 1 is therefore a basic component of every 1-Wire network. The module contains a passive and active terminating resistor and a signaling of bus activity. The active termination (1-Wire Term 1) is highly recommended to increase the maximum line length and improve the system stability of the 1-Wire network, especially for long 1-Wire lines and for a star or tree topology setup. In a 1-Wire network, up to 3 1-Wire Term 1 modules can be connected. The 1-Wire Term 1 is very compact and can be ideally installed in a flush-mounted box. Function Termination for 1-Wire networks, active Channel 1 channel Operating voltage 5VDC, max. 5mA Display 2, LED for power and 1-Wire data Miscellaneous Integrated overvoltage and reverse polarity protection Dimensions 40x40x25mm (LxWxH) Scope of delivery Module and operating instructions Integration into 1-Wire network The 1-Wire Term 1 module is mounted at the end of a 1-Wire network cable. If the 1-Wire network is star-shaped, i.e. with several 1-Wire cable sections, a 1-Wire Term 1 module should be connected to each end. You should not use more than three 1-Wire Term 1 modules in a 1-Wire network. Linear Topology The structure corresponds to the linear topology with the difference that the slaves are connected to the main line via cables with a length of more than 3m (branch, stub).   Star or tree topology The network is divided into several large strings at or near the 1-Wire bus coupler / 1-Wire controller /1-Wire hub (bus master). Sensors and actuators (e.g. switching modules) are connected at the end or along the respective string.   For more information, please refer to the operating instructions under Links/Downloads.

From €33.09*

Product number: 11355

Instantly available
Shipping until , if you place your order within the next .